Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Practical Radiology ; (12): 995-998, 2014.
Article in Chinese | WPRIM | ID: wpr-452226

ABSTRACT

Objective To explore the establishment method of virtual three-dimensional model of the virtual artery and interven-tional devices,and its application value.Methods The virtual models including virtual artery system,catheter,guide wire,stent and coil were established by using the three-dimensional moulding software of 3D Studio MAX R3.The study about interventional preoperative simulation and assistant instruction were run in personal computer.Results ①All the virtual instruments and real in-struments were highly similar shape,the arterial system in the visual display was similar to realistic system.②All arteries branches had own name,could be arbitrarily adjusted curvature,diameter and established the lesion morphology.③The reference value of preoperative simulation results to guide the actual surgery included following aspects:to guide the reasonable shaping of micro-cathe-ter and micro-guide wire tip,to plan the coil and stent deployment location,number and size.④In training and teaching,the preop-erative simulation could assist doctors in learning and remembering the artery branch and establishing the concept of three-dimen-sional space,and enhanceing the intention understanding of surgery.Conclusion The establishment method of virtual model of the virtual artery and interventional devices is reliable.The preoperative simulation results can be used to guide practical operation with relatively high accuracy,and it has an important supporting role for the teaching and training of medical students.

2.
Chinese Journal of Radiology ; (12): 359-362, 2012.
Article in Chinese | WPRIM | ID: wpr-418680

ABSTRACT

Objective To explore virtual three-dimensional (3D)model for intravascular interventional devices,the method of preoperative simulation and its value in clinical work.MethodsThe virtual models including catheter,guide wire,stent and coil were established by using the 3D moulding software of 3D Studio MAX R3. The interventional preoperative simulation was performed on personal computer including 21 patients of cerebral aneurysm embolization ( anterior communicating artery 5,posterior communicating artery 10,middle cerebral artery 3,internal carotid artery 2,and vertebral artery 1 ),during interventional procedures,the surgeon relied on the simulation results for plastic micro-guide wire,catheter and the release of micro-coils and stents.Results( 1 ) All the virtual instruments and real instruments had similar shape,the overall tine for constructing virtual model was about 20 hours.The preoperative simulation took 50 to 80 minutes. (2) The simulation result of catheter insertion in the 18 cases had relevant value to guide micro-catheter,molding micro-guide wire tip,and shortened the operating time.For embolization,the simulation results of filling coil and releasing stent were similar to surgical results in 76% of the patients (16/21).(3)For teaching and training,93% (38/41) of doctors in training believed that preoperative simulation facilitated the understanding of surgery. ConclusionsThe method of virtual model of intravascular interventional devices was reliable.The preoperative simulation results could be used to guide practical clinical operation with relatively high degree of similarity,and could play a role in promoting researches on interventional virtual operations.

SELECTION OF CITATIONS
SEARCH DETAIL